1
Z1-Auto-plugged-in-and-tube_EXP_2

FEATURES

    • Auto adjusting pressure CPAP
    • Auto Start / stop feature
    • Pressure range 4-20 cm H2O
    • Z-Breathe Algorithm for pressure relief
    • Weighs 299g
    • 16.46 cm x 8.38 cm x 5.13 cm
    • FAA compliant for in-flight use
    • Nitelog app via Bluetooth to iOS and Android mobile devices
    • Integrates with Powershell to provide battery powered CPAP treatment
  • Auto Start / stop feature – The Z1 Auto detects when breathing starts in the mask to start the therapy and when the mask is removed to stop the therapy
  • Bright LCD display
  • Programmable ramp mode for gradual acclimation to prescribed pressure
  • Power supply converts voltage ranging from 100-240 volts automatically
  • Internal memory stores sleep data

Technical Specifications

30W Power Adapter

Unit Input range 100–240V, 50–60Hz

Typical power consumption 20W (30VA)

Maximum power consumption 35W (70VA)

Operating temperature 5ºC to 35ºC (41ºF to 95ºF)

Operating humidity 10–80% Relative Humidity, Non-Condensing

Operating altitude Sea level to 2400 m (8,000 ft)

Operating atmospheric pressure 101 to 75.3 kPA

Storage and transport temperature -20ºC to +60ºC (-4ºF to +140ºF)

Storage and transport humidity 10–80% Relative Humidity, Non-Condensing

Storage and transport altitude No limit

Storage and transport atm. pressure No limit

Electromagnetic compatibility Compatible with IEC 60601-1-2

Aircraft use Complies with RTCA DO-160G Standard for use in flight

IEC 60601-1 classification Class II (double insulation), Type BF

Available modes Standby, CPAP, Auto-CPAP and CPAP/Auto-CPAP with Ramp

Sound pressure level < 26 dBA

Nominal dimensions 16.46 cm X 8.38 cm X 5.13 cm (6.48” X 3.30” X 2.02”)

Weight 299 g (10.5 oz)

Housing construction Flame retardant engineered thermoplastic

Supplemental oxygen Not for use with oxygen

Standard air filter Polyester

Air outlet The 22 mm air outlet complies with ISO 5356-1

PowerShell Battery Specifications

99.4 Watt-hours capacity

Lithium Ion Battery Pack

4S2P

Weight approx. 440 g (15.5 oz.)

Performance Specifications

Operating pressure range 4 to 20 cm H2O

Maximum single fault steady pressure 30 cm H2O

Pressure accuracy ±0.6 cm H2O + 4% of the measured reading

*Please contact for availability

Product Details

The steriliser works on the basis that saturated steam at high temperatures has a rapid and thorough bacterial activity. All models work on the idea of downward air displacement, which is the most cost-effective form of sterilising.

Construction

Triple walled steam jacket, with leak-proof argon welding, the inner chamber and steam jacket are composed of stainless steel. Lid S.S. is used to make this item. Ground levelling flanges are screwed to the autoclave, which is fixed on a tubular steel frame.

Pressure Control

All electrically operated sterilisers include a pressure control device. It saves energy by reducing the number of times the steam release valve is opened and preventing steam from entering the room.

Operating Pressure & Temperature

120° C sterilising temperature. 1.2 to 1.5 Kg/cm2 sterilising pressure (15 psi-20 psi). 

Power: Suitable for use with a 440V, 3 phase, 50 Hz AC supply.

  • The use of a vacuum system to remove air from within the chamber ensures that no air pockets obstruct the steam penetration and hence the sterilising process.
  • Standard 121°C & 134°C cycles that are pre-programmed in the memory of the PLC / Microprocessor are used to sterilise a variety of hospital equipment such as gloves, linen, gauze, cotton, tools, glassware, and so on.
  • For all models with a chamber volume of 1000 litres or less, an electrical steam generator is included.
  • The temperature must be kept constant and exact throughout the chamber, within 0.5°C of the Set Sterilization temperature.
  • Internal air-pressure stabilisation from vacuum using a 0.01-micron clean air-filter.
  • When the chamber is under pressure, the door automatically locks. To ensure sterile chain integrity, both doors on double door models will not open at the same time.
  • Safety valves for the jacket and chamber are included.
  • The chamber is made of SS 304/S316 grade steel. The chamber is encircled and strengthened by a thick steel jacket.
  • All machines can be ordered with traditional hinged doors or with Modern Automatic sliding doors.
  • The chamber’s homogeneous and speedy pre-heating is ensured by the double-wall design.
  • On request, a flush-mounted panel can be installed on the sterile side to ensure separation from the unmonitored operating environment.
  • The SS 304 grade SS is used to built our high pressure Horizontal Cylindrical Autoclave
  • The horizontal autoclave is built to last and is ideal for all types of bulk sterilisation jobs in the medical, agricultural, and pharmaceutical industries.
  • Hospital dressing linen, rubber, plastic goods, surgical tools, glass wire, and other items can be sterilised in a horizontal cylindrical autoclave.
  • The chamber’s homogeneous and speedy pre-heating is ensured by the double-wall design.
  • The Horizontal Cylindrical Autoclave is triple walled, has a steam jacket, and is installed on a tubular stainless-steel frame with ground levelling bolted flanges. To reduce heat loss, the outer jacket is lined with mineral wool. Hydraulically, these sterilisers have been tested to withstand 2.5 times the working pressure.
  • The steam generator is built of heavy gauge stainless steel sheet and is fixed in front of the boiler on a heavy ring with folding thick stainless-steel plate. It is equipped with a heating element and a low water level cut-off system to prevent the former from burning out.
  • With the help of a “Multiport Valve” mounted on the front top, the entire sterilisation cycle may be controlled from a single location. On gauges installed on the multiport valve, the jacket and chamber pressures are easily legible.
  • The steriliser is equipped with three levels of safety.
  • At the boiler level, a PIEZOSTAT limits the pressure to the needed set valve and, in the event of its failure; a spring-loaded safety valve releases the steam to keep pressure within the safety limits.
  • A spring-loaded safety valve and a dead weight release valve are installed at the chamber level to release steam if the pressure exceeds the safety limit. All of these safety features work independently of one another in the event of a failure.
  • The discharge pipe is protected against choking by a plug screen. The plug may be readily removed for cleaning on a daily basis. The air is circulated throughout the chamber by a power ejector for drying sterilised lines. A corrosion-resistant metallic wool filter filters the circulating air. A steam trap is installed in the chamber discharge line to automatically remove the condensate.
  • PID Controller operates fully automatically to display the chamber temperature.
  • To break the vacuum created by steam condensation, an automatic vacuum breaker is provided.
  •  

If you’re looking to purchase an autoclave to fulfill your application, please send us your requirements, application data, and desired autoclave accessories. Our technical representative will call you to explore your needs and generate a cost estimate.

Watch Video

Play Video

Request a catalog